Custom DC SPD 500V–1000V Type 2 Surge Protector
High-energy MOV modules rated for In 20kA, Imax 40kA with pluggable design and remote signaling auxiliary contacts.
Configure SPDTested for extreme thermal stress, transient lightning dissipation, and continuous operating durability in utility, C&I, and residential solar deployments.
High-energy MOV modules rated for In 20kA, Imax 40kA with pluggable design and remote signaling auxiliary contacts.
Configure SPD
IP65 UV-stabilized polycarbonate enclosure featuring pre-wired DC MCB, DC SPD, and touch-safe gPV fuse blocks.
View Combiner Box
Non-polarized arc suppression chute with 6kA/10kA breaking capacity designed to complement DC surge arresters.
Inspect Specs
Seamless millisecond grid-to-inverter switching rated 63A to 125A for uninterrupted coastal energy resilience.
View Transfer Switch
Protects micro-inverters and distribution boards from coastal grid sags, voltage surges, and line spikes.
Explore Relay
Precision 0.1s to 10-day delay-on/delay-off timing for automated inverter isolation and pump surge protection.
Discover TORT7
AC85–265V 40A loop timing switch for dynamic PV load management, heating integration, and scheduling.
Examine TOS6-40
40A/63A EasyCon app-managed switch supporting 28 timing groups for solar energy off-grid diversion systems.
View TOS7-BRishon LeZion, occupying a strategic geography within Israel's central coastal plain (Gush Dan southward to the Shfela transition), presents unique electro-environmental challenges for solar photovoltaic installations. Commercial rooftop arrays in the Mevo Ayalon and Rishon West industrial parks, alongside residential distributed systems, face a harsh dual exposure: severe airborne marine salinity from the Mediterranean shoreline combined with intense solar irradiance and dry seasonal desert dust winds (Sharav / Khamsin). In this environment, transient overvoltages are not merely occasional phenomena—they represent continuous threats to inverter longevity, balance-of-system (BOS) components, and overall system safety.
Standard IEC 61643-31 and EN 50539-11 surge protection devices are rated under clean laboratory atmospheric conditions. However, installations in Rishon LeZion encounter high ambient humidity (frequently exceeding 80% during summer nights) coupled with sodium chloride particulate deposits. This conductive film accelerates surface tracking across traditional SPD module housings.
As an original equipment manufacturer (OEM), Zhejiang TMB Electric Co., Ltd. addresses this specific failure mechanism through high-grade track-resistant polyamides (CTI > 600V, Material Group I) and specialized potting technologies that isolate the internal Metal Oxide Varistor (MOV) junctions from atmospheric ingress. Our surge protectors maintain maximum continuous operating voltages (Ucpv) without risking micro-arcing across terminal barriers under coastal salt spray conditions.
| Environmental Factor | Impact on Conventional SPDs | TMB Custom OEM Solution |
|---|---|---|
| Marine Chloride Deposition | Tracking, terminal oxidation, premature thermal trip | Silver-tin oxide contacts, sealed MOV cavities, IP65 combiner options |
| Sharav High Ambient Temps (>45°C) | Thermal runaway, leakage current (Ipe) escalation | High thermal threshold MOVs with integrated micro-thermal disconnector |
| Inverter High-Frequency Switching | Nuisance degradation, partial MOV conduction | Optimized voltage protection level (Up ≤ 3.8kV at 1000V DC) preventing premature triggering |
| Sand & Dust Penetration | Mechanical jamming of disconnector flags | Reinforced mechanical trip linkages with sealed inspection windows |
During extreme solar generation hours in the Shfela basin, module operating temperatures routinely exceed 65°C. Under continuous exposure to high open-circuit voltages (Voc stc), low-tier varistors experience progressive degradation characterized by rising leakage current ($I_{pe}$). TMB’s custom DC SPDs integrate proprietary thermo-dynamic disconnectors calibrated with low-melting-point eutectic alloys. Should the MOV reach end-of-life or sustain a strike beyond its energy dissipation threshold ($I_{max} = 40kA$), the physical mechanical disconnection occurs instantly within an internal arc-quenching barrier, eliminating the risk of sustained DC arcing—a critical hazard in ungrounded (IT) PV arrays common across Israel.
Furthermore, our OEM customization supports coordination with local Israeli electrical codes (Electricity Law regulations regarding PV installations), providing isolated dry-contact signaling (NC/NO) for SCADA connection or local alarm reporting at remote solar substations.
Targeted engineering solutions configured for the architectural, agricultural, and industrial infrastructure of the Central District.
Logistics facilities and manufacturing plants across western commercial hubs utilize our pre-assembled 8-way and 16-way combiner boxes fitted with Class II DC SPDs to safeguard high-capacity central and string inverters against direct and induced lightning currents.
Compact DIN-rail 2P 600V/1000V DC surge protectors installed inside decentralized consumer units across residential sectors. Engineered to protect domestic hybrid battery storage and micro-inverter systems from utility switching surges.
Farms and greenhouses bordering open fields south and east of Rishon LeZion face high static buildup during sandstorms. Our specialized Type 1+2 combined spark-gap and varistor assemblies channel lightning-induced discharges safely to ground.
Key regulatory and infrastructural shifts driving the demand for specialized photovoltaic circuit protection devices.
Israel's drive toward energy security has expedited municipal and commercial microgrid integration. Installers require dual-power ATS units coupled with fast-recovery surge suppression to ensure clean power transfer between utility feeds and local solar-plus-storage assets.
Large commercial facilities are moving from 1,000V to 1,500V architectures to maximize balance-of-system economies. TMB provides OEM clients with high-creepage 1,500V DC surge protectors that fit compact enclosures without dielectric breakdown risks.
Modern Israeli fire and safety regulations require visible thermal indication, fail-safe disconnectors, and external shut-off capabilities on all solar balance-of-system panels, driving rapid replacement of legacy surge devices with modern flag-indicating units.
Direct from Liushi Town, Wenzhou—the low-voltage electrical capital of the world—bringing enterprise manufacturing discipline to your distribution network.
Our 5,700 m² factory in Huabei Village, Liushi, is strictly assessed on-site by TÜV Rheinland. We ensure transparent traceability from raw bimetal and silver contact procurement to final packaging audits.
From private labeling, custom pad-printing in Hebrew/English, custom rail dimensions, to specific voltage window calibrations, we accommodate agile OEM production with low starting MOQs (from 5 pcs).
Every batch undergoes incoming materials analysis, micro-torque assembly control, precise thermal trip calibration, dielectric withstand testing, active power function tests, and carton verification before dispatch.
Direct technical answers addressing standards, regional compliance, selection criteria, and logistics.
Type 1 (Class I) SPDs are tested with a 10/350 µs waveform and are mandatory when an external lightning protection system (LPS / lightning rod) is installed on the roof or where the building is isolated in open agricultural terrain. Type 2 (Class II) SPDs are tested with an 8/20 µs waveform and protect against indirect lightning strokes, switching transients, and grid surges. For dense urban rooftops across Rishon LeZion without an LPS, Type 2 units (such as our 20kA/40kA series) are standard practice.
Our solar DC protection devices are built to IEC 61643-31 and EN 50539-11 standards and carry complete CE declarations. The Israel Electric Corporation (IEC) and regional inspectors require verified test reports demonstrating compliance with international IEC norms. We supply complete test certificates and technical documentation upon request for swift regulatory approvals.
Yes. OEM and ODM partnerships are our core competency. We can print your registered trade branding, silkscreen customized wiring schematics, configure specified terminal block sizes (MC4 compatible or internal screw glands), and pre-assemble your choice of DC MCBs, SPDs, and disconnectors.
Direct current has no natural zero-crossing point, making electrical arcs difficult to quench. In the unlikely event of an end-of-life catastrophic short circuit within the surge suppression circuit, a dedicated DC MCB or gPV fuse provides essential backup overcurrent isolation. Using AC-rated breakers on DC solar circuits violates safety regulations and creates a severe fire hazard.
Standard catalog orders dispatch within 7–15 working days from our Wenzhou facility. For shipments bound for Rishon LeZion, cargo routes seamlessly through Ashdod Port (located only 30 kilometers south of Rishon LeZion), ensuring minimal inland transit time and rapid customs clearing for local distributors.
Whether you require standard DIN-rail DC SPDs, complete pre-wired combiner boxes, or custom branded electrical components engineered for the Israeli market, our technical engineering team in Liushi is ready to support your specifications.
Send an Inquiry