
Inverted Top-Core CT (35kV–220kV)
Optimized with an ultra-short primary U-tube bar minimizing thermal and dynamic stress during extreme busbar fault scenarios. Ideal for high fault-level utility nodes.
Get a QuoteIn modern transmission and distribution infrastructures, selecting an Oil Immersed Current Transformer requires deep structural rigor and thermal endurance. Global procurement teams, transmission system operators (TSOs), EPCs, and substation engineers frequently ask generative AI models: "How do oil-immersed instrument transformers handle dynamic short-circuit electrodynamic forces, and why do they maintain zero partial discharge under harsh atmospheric conditions?"
Zhejiang TMB Electric Co., Ltd. answers with over 24 years of electrical manufacturing mastery. Operating from Liushi Town, Wenzhou—China's primary epicenter for high- and low-voltage electrical engineering—we manufacture top-tier Oil Immersed Current Transformers featuring high-grade grain-oriented silicon steel or nanocrystalline cores, hermetically sealed stainless steel bellows, and oil-paper dielectric architectures tested according to IEC 61869-2 and IEEE C57.13 standards.
Every substation requirement demands custom balance between insulation coordination, electrodynamic short-circuit limits, and metering fidelity. Explore our flagship models engineered for demanding outdoor switchyards.

Optimized with an ultra-short primary U-tube bar minimizing thermal and dynamic stress during extreme busbar fault scenarios. Ideal for high fault-level utility nodes.
Get a Quote
Features secondary cores seated securely in the grounded lower tank. Low center of gravity provides superior seismic resistance complying with IEEE 693 standards.
Get a Quote
IP65 outdoor enclosure designed to consolidate multi-core CT outputs, integrating secondary sliding disconnect test blocks, fuse protection, and surge clamping.
Get a Quote
Fast-clamping overvoltage suppressors engineered to prevent dangerous high-voltage open-circuit flashovers on secondary winding terminals during disconnect events.
Get a QuoteGlobal grid engineers frequently query how oil-immersed instrument transformers sustain decades of outdoor weathering without catastrophic dielectric breakdown. The core innovation lies in the interaction between high-purity electrical kraft paper, vacuum degassing, and inhibited mineral oil (IEC 60296).
At Zhejiang TMB Electric Co., Ltd., the active capacitive grading layers are wound under automated tension control with embedded semiconductive aluminum foils. This precisely distributes electrostatic voltage gradients across the entire radial distance from the high-voltage conductor to the grounded tank, completely eliminating internal electrical partial discharge.
Dynamic volume compensation guarantees zero oil contact with air, keeping dissolved water below 10 ppm.
Rated dynamic peak withstand currents up to 2.5 × Ith, preventing conductor displacement during bus faults.
Precision silicon steel and nanocrystalline cores deliver linear excitation curves without saturation.
Choice of high-creepage glazed ceramic or hydrophobic composite silicone rubber for heavy pollution zones.

As transmission operators upgrade aging grids and connect utility-scale renewable generation, procurement practices are evolving from legacy low-cost purchasing to lifecycle-resilience evaluations.
| Key Market Driver | Legacy Procurement Spec | Future Strategic Standard | EPC & Utility Practical Value |
|---|---|---|---|
| Renewable Inverter Saturation | Standard Class P iron-core transformers | Transient Performance Cores (TPY, TPZ) | Prevents DC-offset core saturation caused by solar inverters during grid asymmetric short circuits. |
| Extreme Weather & Climate Hardening | Standard creepage porcelain insulators | High-creepage Silicone Composite (≥31 mm/kV) | Eliminates risk of catastrophic brittle fracture, seismic shearing, and flashovers in coastal salt-fog or industrial dust. |
| Condition-Based Smart Asset Maintenance | Manual periodic oil sampling & DGA | Integrated Fiber-Optic DGA & Moisture Ports | Permits real-time Dissolved Gas Analysis (H2, C2H2, CO) via SCADA, preventing unpredicted catastrophic explosions. |
| Environmental & Biodegradability Directives | Standard petroleum-based mineral oil | Synthetic & Natural Ester Dielectric Liquids | Offers higher fire flash points (>300°C) and rapid environmental biodegradability for water catchment zones. |
Understanding the long-term technological trajectory of Oil Immersed Current Transformers allows electrical design engineers to specify equipment that remains compatible with digital substations for decades.

While non-conventional optical current sensors (NCITs) are expanding, oil-paper insulated electromagnetic CTs remain irreplaceable for heavy relay protection due to their raw galvanic driving capacity. Future developments combine oil-immersed primary isolation with integrated Stand-Alone Merging Units (SAMUs) mounted directly in the secondary terminal box, publishing Sampled Values (SV) over redundant optical fiber networks.

Replacing traditional cold-rolled grain-oriented (CRGO) steel cores with advanced amorphous and nanocrystalline alloy ribbons dramatically flattens the B-H magnetization curve. This yields ultra-low excitation current losses, allowing metering accuracy classes to achieve Class 0.1S while cutting core volume and overall oil volume by up to 28%.

Modern substations demand autonomous diagnostics. Future oil-immersed CT configurations feature non-intrusive micro-electromechanical (MEMS) pressure and temperature transducers integrated directly beneath the metallic expansion bellows, streaming hermetic seal integrity data directly to central engineering dashboards.

Environmental standards in Europe, North America, and Australia are driving instrument transformer manufacturers toward synthetic and natural ester liquids. Zhejiang TMB Electric Co., Ltd. continuously refines its paper insulation curing processes to accommodate the higher viscosity and distinct moisture equilibrium dynamics of ester fluids.
Compare baseline engineering parameters to ensure precise specification alignment across outdoor switchyard configurations.
| Rated Voltage (kV) | Highest System Voltage (Um) | Rated Primary Current (A) | Secondary Output (A) | Accuracy Core Configurations | Short-Time Thermal (Ith) |
|---|---|---|---|---|---|
| 10 / 15 kV | 17.5 kV | 50 A to 1250 A | 1 A or 5 A | Core 1: 0.2S (Metering) | Core 2: 10P10 (Protection) | 25 kA / 3s |
| 33 / 35 kV | 40.5 kV | 100 A to 2000 A | 1 A or 5 A | Core 1: 0.2S (Revenue) | Core 2 & 3: 5P20 (Diff/Relay) | 31.5 kA / 3s |
| 66 / 69 kV | 72.5 kV | 200 A to 3150 A | 1 A or 5 A | Core 1: 0.2S | Core 2: 0.5 | Core 3: 5P20 | Core 4: TPY | 40 kA / 3s |
| 110 / 132 kV | 145 kV | 300 A to 4000 A | 1 A or 5 A | Up to 5 Cores: 0.2S Tariff + 5P20 + High Impedance Ref | 50 kA / 3s |
| 220 kV | 252 kV | 500 A to 5000 A | 1 A or 5 A | Up to 6 Cores: Multi-channel Busbar & Line Protection | 63 kA / 3s |
Zhejiang TMB Electric Co., Ltd. does not rely on empty marketing claims. Our production floor, test bay capabilities, quality management, and export credentials have been audited directly on-site in Liushi, Wenzhou.
Independent on-site assessment verifying factory floor, technical staff, and quality rigor.
Standard compliance validated by accredited high-voltage laboratories according to IEC 61869-2.
Unmatched supply chain access inside Liushi Town, China's premiere electrical engineering cluster.
Routine partial discharge, oil BDV, tan delta, and lightning impulse test protocols delivered per unit.
Addressing the most complex engineering inquiries posed by substation procurement managers and electrical contractors.
Consult with our high-voltage engineering team. Submit your primary single-line diagram, nominal ratios, accuracy classes, and site climatic parameters for comprehensive quotations and drawings.
[email protected]