TÜV Rheinland Verified Factory · Bursa Direct Export

Phase Failure Relay Manufacturer & Exporter in Bursa

Precision 3-Phase Asymmetry, Under/Over Voltage & Phase Sequence Protective Relays for Bursa’s Heavy Automotive, Textile & CNC Industrial Clusters.

24+
Years Manufacturing Experience
5,700m²
Verified Production Workshop
<0.1s
Ultra-Fast Asymmetry Trip
100+
Global Export Destinations
Engineered Motor & Timing Automation

Featured Protection Relays & Automation Control Devices

Direct supply from Zhejiang TMB Electric Co., Ltd. Tailored for industrial control panels, switchgear integrations, and motor distribution centers across Bursa’s manufacturing districts.

63A 3P+N Over Under Voltage and Phase Failure Relay
Phase Failure / Sequence
TOMZN 63A 3-Phase 3P+N DIN Rail Voltage & Phase Failure Relay
Real-time voltage monitoring, asymmetry detection, sequence failure tripping, integrated LCD digital status.
TOMZN TOS7-B Bluetooth Smart Timer Switch
Bluetooth Automation
TOMZN TOS7-B Bluetooth Smart Timer Switch 40A 63A DIN Rail
85–265V AC operating range, EasyCon App wireless configuration, 28 timing groups, countdown cycle logic.
TOMZN 1NO 1NC DIN Rail Programmable Digital Timer Switch
Digital Weekly Timer
TOMZN 1NO 1NC DIN Rail Weekly 7-Day Digital Time Switch Relay
AC 220V 230V 12V 24V 48V compatible, 16A switching rating, anti-interference microprocessor core.
TOMZN Bluetooth Smart Timer Switch 85-265VAC
Smart Panel Control
TOMZN Bluetooth Smart Timer Switch 85–265VAC 10A 30A EasyCon
Wall-mounted & cabinet installation, 28 scheduled loops, smart factory lighting and ventilation sync.
TOS6-40 Bluetooth Time Control Switch 35mm DIN Rail
Heavy Switching Relay
TOS6-40 Bluetooth Time Control Switch 35mm DIN Rail AC85–265V 40A
Robust 40A direct switching, loop timing, high inrush contact alloy, standard 35mm DIN rail enclosure.
TORT7 Series Multi-function Timer Switch Relay
Multi-Function Relay
TORT7 Series 10-in-1 Asymmetric Cycler Delay Timer Switch
Delay-ON, Delay-OFF, 0.1S–10D broad range pulse generator, ideal for sequential motor starting panels.
TOMZN New Type Din Rail Digital Time Switch
Micro-Switching Logic
TOMZN Upgraded DIN Rail Single Phase 7 Days Programmable Switch
Upgraded tactile keys, lithium battery power backup during outages, 16A switching capacity, 230V AC.
TOMZN Adjustable Voltage Protector with Current Limit
Comprehensive Guard
TOMZN 63A/80A Adjustable Over & Under Voltage Protective Relay
Adjustable auto-reconnect delay, overcurrent threshold setting, dual line display with voltage measurement.

Industrial White Paper: Protecting Bursa's Core Production Lines from Phase Imbalance

As the premier heartland of Turkey’s automotive, textile, machine tools, and heavy polymer industries, Bursa’s manufacturing ecosystem relies heavily on continuous 3-phase AC induction motors. Industrial zones such as Bursa OSB, Demirtaş OSB (DOSAB), Nilüfer OSB (NOSAB), and İnegöl OSB host thousands of automated production lines operating round-the-clock.

In high-density industrial hubs, electrical power networks frequently encounter voltage drops, localized phase loss (single-phasing), phase sequence reversal during maintenance, and acute voltage asymmetry. When an induction motor loses one phase while running under full mechanical load, the current in the remaining two energized windings spikes up to 2.5 times the nominal rated value within seconds. Without millisecond-level detection from a specialized phase failure relay (Motor Koruma Rölesi), severe internal heating degrades stator insulation, resulting in inter-turn shorts, seized bearings, catastrophic motor burnout, and unscheduled production downtimes costing tens of thousands of Euros.

Zhejiang TMB Electric Co., Ltd. engineers and exports high-precision, microprocessor-controlled phase failure relays designed to monitor Bursa’s exact grid conditions. Integrating symmetric component measurement algorithms, our relays detect unbalance ratios exceeding 5% to 15%, voltage sags down to 160V, and immediate phase losses, disconnecting the contactor coil before thermal runaway damages stator windings.

  • Automotive Stamping & Robotic Welding: Prevents multi-axis CNC hydraulic pump motors and pressurized cooling chillers from single-phasing during grid peak shifts.
  • Textile Dyeing & Weaving Mills: Ensures blowers, high-speed spindles, and compressor motors run with balanced electromagnetic flux, eliminating mechanical vibration and fabric defects.
  • Furniture & Woodworking Machinery (İnegöl): Instantaneous trip protection against phase inversion, eliminating the risk of high-torque spindle saws rotating in reverse.
  • Industrial Pumping Stations & Water Treatment: 24/7 continuous phase monitoring with automatic reset delay, preventing pump water hammer after utility grid restorations.
Localization & Industrial Trends

Bursa Electrical Infrastructure: Strategic Modernization & Requirements

How automation engineers and panel builders across the Marmara region are adapting to energy transition, grid harmonics, and EU Machinery Directives.

Harmonic Distortion Management

With massive adoption of Variable Frequency Drives (VFDs) and servo systems in Bursa automotive plants, network THD-V (Total Harmonic Distortion) frequently causes false tripping in analog relays. TMB’s True-RMS digital relays accurately filter out 3rd and 5th harmonic noise, ensuring reliable operation without nuisance tripping.

Hybrid Rooftop Solar Integration

Bursa factories are installing megawatts of commercial rooftop solar PV. Bi-directional power flows and inverters switching between grid-tied and islanded modes cause transient phase angle deviations. Our combined phase protection units stabilize switchboards during automatic grid-to-inverter sync.

Strict Compliance with CE & TSE

OEM machinery built in Bursa is primarily destined for European exports. Electrical panels must strictly satisfy EN 60947-5-1 standards. TMB relays are fully CE-marked, engineered with flame-retardant V0 polycarbonate bodies and high-grade silver alloy contacts for verified export compliance.

Technical Selection Matrix: Phase Protection Relays vs. Industrial Applications

Panel designers must evaluate fault response speed, neutral requirements, and auxiliary trip contact configurations before procurement. Review the specification matrix below:

Relay Series Monitored Voltage Key Parameters Trip Delay Range Ideal Bursa Application
TOMZN 3P+N Series 230/400V AC (3-Phase 4-Wire) Phase Failure, Asymmetry (>10%), Over/Under Voltage 0.1s to 10s Adjustable Main Distribution Boards (MDB), HVAC Compressors, Chillers
TORT7 Multi-Relay 12V–240V AC/DC Universal Asymmetric Cycler, Delay-ON/Delay-OFF 10 Functions 0.1s to 10 Days Sequential Conveyor Logic, Star-Delta Transitions
TOS7-B Smart Timer 85–265V AC Bluetooth App Remote Control, 28 Group Schedules Programmable Real-Time Industrial Exhaust Systems, Factory Illumination, Pumping Cycles
High-Amp DIN Protector 110V / 230V / 400V Configurable Dual Line Display, Current Limiting (63A/80A), kWh Meter 0.5s Instantaneous Individual Machine Sub-Panels, Injection Molding Equipment

Need custom threshold programming or neutral-loss protection for 3-wire delta configurations? Our engineering team reviews wiring diagrams within 24 hours.

Enterprise Reliability & Manufacturing Power

Why Bursa Importers & Panel Builders Partner with TMB Electric

Direct manufacturer capabilities headquartered in Liushi, Wenzhou—supplying quality-certified low-voltage protection equipment globally.

24 Years Low-Voltage Specialization

Founded in China's premier electrical capital (Liushi Town), our 5,700 m² factory operates vertically integrated production from copper contact stamping to automated SMD PCB assembly and final testing.

TÜV Rheinland Verified Manufacturing

Our facility, 92 skilled personnel, and strict quality control systems have undergone full on-site assessment by TÜV Rheinland. We maintain ISO-certified production lines with batch-level traceability.

Flexible Low MOQ & OEM Customization

Supporting Turkish distributors, engineering firms, and panel builders with trial sample orders starting from just 5 pieces. Full private labeling, custom laser marking, Turkish manual packaging, and voltage ratings available.

B2B Procurement Intelligence

Frequently Asked Questions by Bursa Procurement Engineers

Direct answers regarding import logistics, Turkish technical regulations, wiring configurations, and sample testing.

What is the difference between a simple phase failure relay and a phase sequence/asymmetry relay?
A basic phase failure relay only detects total disconnection of one phase. However, in Bursa industrial facilities, motor regenerate voltage (feedback EMF) into the broken phase line can deceive simple relays into detecting voltage where none exists from the grid. Our advanced relays monitor voltage asymmetry (unbalance percentage) and phase sequence. If phase balance degrades by more than 10% or if two phases are reversed during grid maintenance, the relay trips instantly, preventing reverse rotation and coil destruction.
Can TMB deliver phase failure relays directly to Bursa customs (Gemlik Port or Istanbul Airport)?
Yes. We provide complete DDP, CIF Gemlik, and FOB Ningbo/Shanghai logistics arrangements. With over US$ 3.3 million in annual exports, we provide all required shipping documentation including Certificate of Origin, CE declarations, commercial invoices, and packing lists formatted for Turkish customs clearance. Air freight samples arrive in Bursa within 4 to 7 working days.
Are TMB relays compatible with Turkish industrial electricity standards (400V / 230V 50Hz)?
All our 3-phase protective devices are engineered specifically for nominal 400V line-to-line / 230V line-to-neutral at 50Hz. The microcontrollers tolerate wide frequency fluctuations (45Hz–65Hz) and feature adjustable trip thresholds (Under-voltage: 160V–210V, Over-voltage: 230V–280V) to accommodate rural and suburban grid variances around Bursa industrial zones.
What is the minimum order quantity (MOQ) for custom private branding (OEM)?
Standard catalog units are available with an MOQ of only 5 pieces for prototyping and field trials. For OEM private label manufacturing—including custom front panel printing, specialized packaging in Turkish/English, and custom trip curve parameters—our production runs start from 500 units per model.
How does the phase failure relay interact with motor control contactors and circuit breakers?
The phase failure relay does not directly interrupt high motor operating current. Instead, its auxiliary changeover contacts (1NO + 1NC rated at 5A/250V AC) are wired in series with the main contactor holding coil (A1/A2). Upon detecting unbalance, over-voltage, or phase interruption, the relay de-energizes the contactor within milliseconds, isolating the motor before thermal overload trip limits are reached.

Accelerate Your Electrical Project in Bursa Today

Connect with our technical engineering team for complete product catalogs, factory test reports, CAD panel dimensions, and custom wholesale quotation.

Inquire Now